Online leaking sealing for valve body 3" class #2500
- Survey, calculate data, design, process and manufacture clamps.
- Install clamp, inject glue for online leak sealing of valve body (3" #2500).
Parameter:
- Working pressure: 10Mpa.
- Temperature: 300 degrees Celsius.
- Medium: water.