- Turbine repair and maintenance: Disassemble, repair, maintain, alignment, reinstall.
- Blasting by aluminum powder to clean turbine rotors and diaphragms.
- Repair and maintenance of 60MW generator.
- Repair and maintenance of Stop valve, Steam Turbine Regulating Valve system.
- Repair and maintenance of oil pumps, oil coolers, etc.
- Dynamic balancing of the turbine rotor.
- Vibration analysis of the turbine-generator-exciter system.
Other Projects
Online Leak sealing for CO Coal Gas Pipeline
Cleaning CW heat exchangers
Dynamic balancing for pump impeller 022-P-216A
On-line leak sealing for the water supply pipe for the absorber